: The device features a clear LED digital display that shows both the current temperature (PV) and the target setpoint (SV). The Hero’s Journey: Setup and Operation
The unit typically uses three main buttons: , Left Arrow (<) , and Up/Down Arrows ( ) . 3.1 Changing the Setpoint (SV)
| Parameter | Value / Details | | ----------------------------- | -------------------------------------------------------------------------------------------------------------------------------------------- | | | XMTG-2000 series (e.g., XMTG-2001, XMTG-2002, etc.) | | Display Type | 4-digit LED / LCD | | Display Range | -1999 to 9999 | | Measurement Accuracy | ≤ 1.0% FS ± 1 digit (0.5% FS for some models) | | Input Types | Thermocouple (K, J, E, S, B, T), RTD (Pt100, Cu50) | | Control Mode | PID (Proportional-Integral-Derivative) | | Output Options | Relay (3A @ 220V AC resistive), SSR (0-12V DC), 4-20mA, 1-5V, etc. | | Power Supply | 90-242V AC, 50/60 Hz | | Power Consumption | < 3W | | Panel Cutout Dimension | 45 x 45 mm | | External Dimensions (WxHxD) | 48 x 48 x 110 mm | | Weight | Approximately 0.3 kg | | Operating Temperature | 0 to 50℃ | | Relative Humidity | < 85% RH (non-condensing) | xmtg-2000 temperature controller manual pdf
Connect the positive wire to terminal 7 and the negative wire to terminal 8.
Dual-line 4-digit LED display (Process Value in Red, Set Value in Green). : The device features a clear LED digital
Depending on the exact model suffix, your output will use one of the following:
| Parameter Code | Description | Typical Setting | | -------------- | -------------------------------------------------- | ------------------------------------------------- | | | Proportional Band (0-9999) | Set based on PID autotuning results | | I | Integral Time (0-3600 seconds) | Set based on PID autotuning results | | D | Derivative Time (0-3600 seconds) | Set based on PID autotuning results | | AL1 | Alarm 1 value | Sets the high alarm threshold | | AL2 | Alarm 2 value | Sets the low alarm threshold | | SN | Input sensor selection | Select your sensor type: 'K', 'PT1', 'Pt100', etc. | | DP | Decimal point position | Set if displaying non-integer values | | At | PID Autotuning Enable/Disable | Set to '1' or 'ON' to start autotuning | Dual-line 4-digit LED display (Process Value in Red,
Relay Contact, SSR (Solid State Relay) Voltage Drive, or 4-20mA Current 0.5% FS (Full Scale) ± 1 Digit Power Supply 85–264V AC, 50/60Hz Dimensions 48mm x 48mm (Front Panel Panel Cutout) Panel Layout and Button Functions